Device Data
Every symbol instance on a sheet hangs from a 设备 (device) record. Device records are the single source of truth shared by the BOM, the terminal schedule, and cross-references: a device's coil, its contacts, and any number of scattered symbols all share one tag and one set of model information.
Device data fields
Select a component and you can edit seven fields in the 设备信息 (Device Data) section of the inspector:
| Field | Purpose |
|---|---|
| 代号 (Tag) | The item reference, e.g. QM1, KM1, KA3. The BOM and cross-references group by it, and it should be unique across the project. |
| 名称 (Name) | Device name, e.g. “交流接触器” (_AC contactor_). |
| 型号 (Model) | Ordering model number, e.g. LC1D09. |
| 规格 (Rating) | Key ratings, e.g. 9A 220V AC. |
| 物料编码 (Material code) | Your company's internal part code; exported as its own column in the BOM. |
| 制造商 (Manufacturer) | Brand / maker. |
| 备注 (Notes) | Free text, ending up in the BOM's notes column. |
Automatic tag generation
When you place a component, EletraDraw takes the letter prefix of the symbol code and appends the highest existing
sequence number of that kind on the current page/project plus one — so the second AC contactor becomes
KM2. Terminals (XT), earth (PE), and interruption points do not participate in
the automatic tag sequence. The generated value is only a starting point: you can rewrite the Tag at
any time to match your company's conventions, such as -KM1 or 3KM1.
If two devices use the same tag, the Electrical Check reports “设备代号「KM1」重复出现 2 次” (_device tag “KM1” appears 2 times_), and in the Pro version the canvas also marks the affected components with a red !.
Linking to one device
A real-world part often appears several times on a drawing: the coil in the main circuit, several auxiliary contact groups, multi-contact symbols from the library. Point them all at the same device record:
- Select the scattered symbol (say, a normally-open contact) and open the 关联到已有设备 (Link to Existing Device) drop-down in Device Data.
- The list shows the other devices in the form “
KM1 · 交流接触器”; picking one completes the link. When the project contains only one device it shows 暂无其他设备 (No other devices yet). - After linking, editing these fields is synchronized: change the Model on any symbol and every symbol of the same device updates. In the undo list the corresponding action names are 关联设备 (_Link Device_) and 修改设备属性 (_Modify Device Attributes_).
Tip
There is no “unlink” button. The interface only offers “Link to Existing Device”. To separate a symbol from its device, simply change its Tag to a new, unused value; two symbols written with the same tag are the same device.
What linking gives you
- Cross-references (交叉引用): once a coil and its contacts are linked to the same device, labels pointing at each other's locations are generated automatically (the Cross-References section of the inspector lists them as “contact/coil + page name · zone”). This is a Pro feature; in the free version that section shows the 交叉引用(Pro) (Cross-References (Pro)) explanation instead.
- BOM: one row per device — see BOM (Bill of Materials).
- Terminal schedule: terminal symbols are grouped by device and terminal rail — see Terminal Schedule.
The “端子” (Terminal) section at the top of the inspector — present only for terminal-type symbols — offers three fields: 端子排 (Terminal Rail), 端子号 (Terminal Number), and 备注 (Notes). They write back into the device record and become columns of the terminal schedule directly; see Terminal Schedule for details.