Electrical Rules Check

The command is 图纸 ▸ 电气检查 (Drawing ▸ Electrical Check, ⇧⌘E), and the result is a plain-text list that pops up over the canvas. Electrical Rules Check is a Pro feature; in the free version the command only shows an alert reading “电气检查是 Pro 功能” (Electrical Check is a Pro feature).

What is checked

The app ships 4 built-in check categories, which produce 5 message strings (the off-page connector check has a separate “未命名” (unnamed) and “未配对” (unpaired) message):

CheckExample report textLikely cause and fix
Dangling pin· “[图纸 1] KM1 的引脚「A2」悬空未连接”
([Sheet 1] pin “A2” of KM1 is dangling, not connected)
The pin has no wire at all, or a wire endpoint was dragged off the connection point. Draw the missing wire, or confirm the pin really is spare (an unused contact, for example) and then ignore it.
Duplicate device tag· “[图纸 2] 设备代号「KA1」重复出现 2 次”
([Sheet 2] device tag “KA1” appears 2 times)
Two different components carry the same tag: either change the 代号 (tag) on one of them, or — if they are one and the same device — 关联到已有设备 (link them to the existing device) (see Device Information and Linking).
Unnamed off-page connector· “[图纸 3] 中断点未设置网络名称”
([Sheet 3] the off-page connector has no network name set)
Type it in the properties panel under 跨页中断点 ▸ 网络名 (Off-Page Connector ▸ Network Name).
Unpaired off-page connector· “[图纸 3] 中断点「QP2」缺少配对的目标/源”
([Sheet 3] off-page connector “QP2” is missing its paired target/source)
There is only a source and no target (or the other way round). Place an 中断点目标 (off-page connector target) with the same name on the other page — the names must match exactly.
Junction with too few wires· “[图纸 1] 接点连接导线不足 2 根”
([Sheet 1] the junction is connected by fewer than 2 wires)
Only one wire is left on the junction (usually after a deletion or a dragged-off endpoint). Add a wire back, or delete the junction.

The check runs over every sheet of the whole project. The pins of an off-page connector symbol are not counted as dangling, because that connection is expressed by name pairing instead of by wires.

Reading the result

Warning

There is no “ignore this issue” and no “fix all”. Results cannot be dismissed one by one, and there are neither repair suggestions nor automatic changes. “Correctly dangling” pins — spare contacts, pins deliberately left open — can only be explained with a text annotation. The report is not stored either: once the dialog is closed it is gone.

Recommendations

  1. Run the check after every circuit you finish; it is much easier to locate a problem than one big pass over the whole set.
  2. Suggested order: fix duplicate device tags first (they affect the BOM and cross-references), then the off-page connector issues (they affect network merging and wire numbers), and finally the dangling pins and junctions.
  3. Run it once more before you export, and archive the result together with your deliverables (the dialog text has to be copied by hand — it cannot be exported).