Wire Numbers

A wire number is the identifier carried by a wire (e.g. L1, K5, PE). One electrical connectivity shares one wire number: a group of wires merged by junctions, or a single potential network, all carry the same number.

Numbering Entry Points

CommandLocationBehavior
全部重新编号 (Renumber All)图纸 ▸ 全部重新编号 (Sheet ▸ Renumber All, ⇧⌘R) Renumbers every unlocked wire number across all sheets of the drawing, according to the current rules.
仅选中导线重新编号 (Renumber Selected Wires Only)图纸 ▸ 线号 (Sheet ▸ Wire Numbers) Renumbers only the selected wires (unavailable when nothing is selected). Each hit wire takes the same number as its group/network members.
线号规则… (Wire Number Rules…)图纸 ▸ 线号 Opens the rules panel. A Pro feature; in the free version the item reads 线号规则…(Pro) and clicking it shows the Pro explainer.

The Wire Numbering Rules Panel

The panel (titled 线号编号规则, Wire Numbering Rules) has six settings and two buttons, 取消 (Cancel) / 应用 (Apply):

FieldDefaultDescription
主回路前缀 (Main-circuit prefix)LUsed for networks connected to 电源输入/电源输出 (power input/power output) pins.
控制回路前缀 (Control-circuit prefix)KUsed for networks connected to 信号输入/信号输出 (signal input/signal output) pins.
信号回路前缀 (Signal-circuit prefix)WThe fallback prefix for all other networks (passive pins, unconnected pins, etc.).
起始序号 (Start number)1Each prefix starts counting from this number independently.
步长 (Step)1E.g. start 1 + step 10 yields L1、L11、L21… (L1, L11, L21…)
编号方式 (Numbering mode)按图纸顺序 (By sheet order) Options: 按图纸顺序 (By sheet order), 按电位网络 (By potential network), 按分区 (By zone) — see below.

The note at the bottom of the panel reads: 锁定线号在重新编号时会被保留;接地网络统一编号为 PE。 (Locked wire numbers are preserved on renumbering; grounding networks are numbered PE as one.)

Choosing a Numbering Mode

Tip

Fixed potential names take priority over prefix + number. When symbol pins carry a potential group (N, L1/L2/L3, DC24V, 0V, SG, etc.), the wire adopts that name directly as its number and consumes no sequence; all ground-type pins (PE), once merged, are numbered PE as one. This is why three-phase incoming lines show L1, L2, L3 rather than L4, L5, L6. If a kind of component (for example an interrupt) has pins without a potential group, the networks it joins fall back to prefix + number, which may disagree with your expected "same number across pages" — in that case switch to by potential network or fill in the number by hand.

Manual Numbers and Locking

Where Wire Numbers Appear

The number is drawn at the midpoint of the wire's longest segment: above and centered for a horizontal segment, to the right for a vertical segment. Label placement is chosen by the automatic layout engine, which avoids components, other wires, text, potential names, and the title block; if the automatic position is not what you want, drag the label directly (the drag is remembered), or double-click it / right-click and choose 恢复标签自动布局 (Restore Label Auto Layout) to hand it back to the program. See the note on labels at the end of Interrupts and Cross-References.